Skip to content
Mallikarjuna StonesShahabad limestone · Karnataka to the UK

Tested, not assumed

Independently tested to the relevant BS EN standards

Our Shahabad limestone range is independently laboratory tested against the BS EN standards a UK specifier expects to see, with batch testing carried out on production runs and a Declaration of Performance and UKCA marking issued with every shipment.

Test results

Reference results by standard

PropertyStandardTypical result
Compressive strengthBS EN 1926≥ 65 MPa
Flexural strength (concentrated load)BS EN 12372≥ 9 MPa
Water absorption at atmospheric pressureBS EN 137553.5–4.5% by mass
Density and open porosityBS EN 19362,450–2,550 kg/m³
Abrasion resistance (wide disc)BS EN 14157≤ 21 mm groove length
Slip resistance, wet (pendulum)EN 16165 Annex CPTV 45–55 depending on finish
Frost resistance (freeze-thaw cycling)BS EN 12371No loss of flexural strength after 48 cycles

Figures above are reference results for the range and are confirmed again on a batch basis. Certificates for the specific batch behind your order are issued alongside the commercial documents and are available on request before you place it.

Sampling

Sample before order

We do not take an order against a photograph alone. Every enquiry that proceeds to quote can be offered a physical sample cut from current stock, so a buyer can inspect colour, finish and general condition of the stone before committing.

A sample confirms colour, finish and feel; the test results above confirm the engineering figures behind them. Between the two, a specifier has both what the stone looks like and how it performs.

At the yard

In-process checks and batch testing

  • 01

    Block selection

    Blocks assessed visually for fracture, colour and bedding consistency before cutting.

  • 02

    Cutting

    Slabs cut to the ordered size at the yard.

  • 03

    Honing and polishing

    Finish applied on-site to the ordered specification.

  • 04

    Pre-crating inspection

    Visual and dimensional check for edge chipping, staining and visible fracture before a piece is wrapped.

  • 05

    Crating

    Crate contents checked against the packing list before the lid is fixed.

Visual and dimensional checks at the yard run alongside independent laboratory batch testing, which is repeated on each production run rather than carried forward indefinitely from a single certificate.

Conformity

Declarations and marking

We issue a Declaration of Performance and apply UKCA marking to consignments covered by a harmonised product standard, referencing the test results above and the specific batch shipped. Certificates are provided with the commercial documents for every order and are available in advance on request.

Ask for the certificates

Request test certificates alongside your sample

Request a sample, or ask us directly for the Declaration of Performance and batch test certificates for your specification before you commit to an order.